A complete processing solution from biomass to crude and/or distillate. Features dual high-speed batch centrifuges with closed-loop extraction routines utilizing ultra-cold temperature ethanol solvent enabling complete and high-quality cannabinoid capture without the need for winterization. Multi-stage filtration utilizes both particulate and color remediation with inter-stage pressure sensors and sight glasses for quality feedback. Closed loop solvent recovery with desolventizing and decarb routines enables full spectrum crude production under vacuum and reduced heat conditions with no need for roto-vaps or vac ovens for final oil processing.
Dual pass distillation module enables crude oil refinement utilizing terp strip and final distillation routines. Complete system automation enables touch button control with tunable parameters for single-operator control. A closed loop process with integrated heated lines and pumps eliminates open pours and the need for external heat sources such as heat guns, tape, etc.
Jacketed & insulated holding tanks allow cold solvent and tincture temps to be maintained while reducing system energy consumption.
Dedicated C1D2 HMI control interface allows automated hands-free extraction control at the point of use for precise, repeatable extractions with real-time performance feedback.
Dual high-speed batch centrifuge extraction module with closed loop tincture re-use routines includes integrated heat exchangers, automated valves, and sensors for touchless control. post-extraction clean solvent rinse increases extraction efficiencies
Particulate & color remediation module filters cold extract directly from extraction, eliminating the need for winterization. Staged sight glasses allow product quality to be observed and maintained at all times.
RFE (Rising Film) & FFE (Falling Film) evaporator enables bulk solvent evaporation under vacuum at reduced temperatures to maintain product quality and profile.
In-Line Sample Test Ports enable direct sampling of substances from within the system while maintaining a vacuum environment.
Desolventizing reactor vessels remove residual solvent and enable in-place decarb routines for true hands-free processing to a full spectrum crude final product. Dual vessels enable continuous extraction capability eliminating the need for rotovaps.
Jacketed & heated lines enable product transfer without the need for heat guns or other manual heating needs.
Stainless steel drip trays under interface points to contain any product spills and allow for easy cleaning and product recovery.
Wiped Film (WFE) dual-pass distillation module features a heated feed tank with metering gear pump, 6" wiped film still with mechanical seal, dual cold traps for complete light volatile recovery, and mtorr high vacuum system complete with diffusion and roughing pumps. TCU's maintain precise temperature control of WFE jacket up to 200° C, inner condenser temp up to 130° C and cold trap temps down to -80° C. Residue and distillate offtake pumps allow continuous hands-free processing to distillate.
Dedicated distillation control interface allows automated hands-free distillation control at point of use with real-time performance feedback.
Jacketed & insulated holding tanks allow cold solvent and tincture temps to be maintained while reducing system energy consumption.
Dedicated C1D2 HMI control interface allows automated hands-free extraction control at the point of use for precise, repeatable extractions with real-time performance feedback.
Dual high-speed batch centrifuge extraction module with closed loop tincture re-use routines includes integrated heat exchangers, automated valves, and sensors for touchless control. post-extraction clean solvent rinse increases extraction efficiencies
Particulate & color remediation module filters cold extract directly from extraction, eliminating the need for winterization. Staged sight glasses allow product quality to be observed and maintained at all times.
RFE (Rising Film) & FFE (Falling Film) evaporator enables bulk solvent evaporation under vacuum at reduced temperatures to maintain product quality and profile.
In-Line Sample Test Ports enable direct sampling of substances from within the system while maintaining a vacuum environment.
Desolventizing reactor vessels remove residual solvent and enable in-place decarb routines for true hands-free processing to a full spectrum crude final product. Dual vessels enable continuous extraction capability eliminating the need for rotovaps.
Jacketed & heated lines enable product transfer without the need for heat guns or other manual heating needs.
Stainless steel drip trays under interface points to contain any product spills and allow for easy cleaning and product recovery.
Wiped Film (WFE) dual-pass distillation module features a heated feed tank with metering gear pump, 6″ wiped film still with mechanical seal, dual cold traps for complete light volatile recovery, and mtorr high vacuum system complete with diffusion and roughing pumps. TCU’s maintain precise temperature control of WFE jacket up to 200° C, inner condenser temp up to 130° C and cold trap temps down to -80° C. Residue and distillate offtake pumps allow continuous hands-free processing to distillate.
Dedicated distillation control interface allows automated hands-free distillation control at point of use with real-time performance feedback.
Extraction carousel with user configured routines and flow control from biomass to full spectrum crude, distillate and/or isolate.
Bypass this extensive and time-consuming step by controlling and maintaining solvent temperature during the extraction process below -50 °C.
From your phone or computer, real-time and trend monitoring of extraction process can be leveraged to optimize efficiency.
Solvent temperature control maintains precise extraction temperature. Combined with our automation, complete control over final product states can be configured and run.
No touch process throughout the extraction process eliminates potential reduced efficiencies, compromised quality, increased labor and safety risks.
Heated and jacketed lines in extraction systems maintain consistent temperatures, preventing solidification or degradation of sensitive substances. This technology enhances extraction yields, quality, and streamlines operations by eliminating external heating devices
In-line sample test ports enable direct sampling of substances from within the system while maintaining a vacuum environment. This feature allows for real-time quality checks and process monitoring without disrupting the extraction process or compromising the vacuum conditions, ensuring accuracy and efficiency in product testing.
Our systems are designed for optimization on each of your processes.
Batch Size: up to 35 lbs
Throughput Capacity: 1800 lbs per day
Temperature Range: Configurable down to -60C
Voltage: 208 / 240 / 480 (configurable)
Power: 60 kW (not including chiller)
Electrical Rating: Class 1 Div 2
MINIMUM ELECTRICAL RATING
Footprint: 30’ W x 7’ D x 10’ H (TOTAL SYSTEM FOOTPRINT)
Temperature Rating: -60 to 200 C
Pressure Rating: Vacuum to 50 PSIG
Solvent Holding Volume: 110 gallons
HMI Interface: Dual 24 Inch Touch Panel (C1D2 rated)
Controller: FPGA Industrial Controller w/ Watchdog (C1D2 rated)